Functional Neurosurgery
functionalneuro.surgery
Functionalneurosurgery.net

IOM Sites
iomonitoring.org
operativemonitoring.com

Neurosurgical Sites
neurosurgery.art
neurosurgery.me
neurosurgery.mx
skullbase.surgery

Neurosurgical Encyclopedia
neurosurgicalencyclopedia.org

Neurooncological Sites
acousticschwannoma.com
craniopharyngiomas.com
ependymomas.com
gliomas.info
gliomas.uk
meningiomas.org
neurooncology.me
pinealomas.com
pituitaryadenomas.com 

Neuroanatomical Sites
humanneuroanatomy.com 
microneuroanatomy.com

Neuroanesthesia Sites
neuro-anesthessia.org

Neurobiological Sites
humanneurobiology.com

Neurohistopathological
neurorhistopathology.com

Neuro ICU Site
neuroicu.info

Neuroophthalmological
neuroophthalmology.org

Neurophysiological Sites
humanneurophysiology.com

Neuroradiological Sites
neuroradiology.today

NeuroSience Sites
neuro.science

Neurovascular Sites
vascularneurosurgery.com

Personal Sites
cns.clinic

Spine Surgery Sites
spine.surgery
spondylolisthesis.info
paraplegia.today

Stem Cell Therapy Site
neurostemcell.com


 

Inomed Stockert Neuro N50. A versatile
RF lesion generator and stimulator for
countless applications and many uses


 

Multigen RF lesion generator .

 06-DECEMBER-2003  NAEL ABDEL-SATAR ABDEEN  38 YEARS  UNSTABLE BURST FRACTURE L1 WITH COMPRESSION.

 

Anamnesis

bullet

The patient felt down 04-December-2003 and got burst fracture L1 with bony compression to the spinal cord. CT-scan and MRI done showing unstable fracture L1 with bony compression of the spinal cord.

bullet

On examination, the patient in bed with Foley's catheter, but neurologically free.

bullet

Skeletonization of L3,2,1,D12 and D11 with preservation of the intraspinous ligaments. Using Harrington rods, distraction, reduction and fusion of the mentioned area was achieved aided with sublaminar wires to D11.

bullet

Smooth postoperative recovery and the patient ambulated the next day.

FOLLOW UP

bullet

The patient came to the clinic 17-December-2003 with clean wound and neurologically free. SLRS was 80 degrees without pain.

bullet

The patient came 25-January-2004 with new X-rays showing good reduction of the bone and good alignment of the construct.

bullet

The patient then came 26-July-2005 with the upper part of the right rod is flail and advised for removal.

 

Comments

bullet

The Harrington rods are good, but they are intended for temporary insertion, to be removed after 8-10 months.

 

Skyra MRI with all clinical applications in the run since 28-Novemeber-2013.


Inomed Riechert-Mundinger System, with three point fixation is the most accurate system in the market. The microdrive and its sensor gives feed back about the localization.


Inomed MER system

Leica HM500

Leica HM500
The World's first and the only Head mounted Microscope.
Freedom combined with Outstanding Vision, but very bad video recording and documentation.

TRUMPF TruSystem 7500

After long years TRUMPF TruSystem 7500 is running with in the neurosuite at Shmaisani hospital starting from 23-March-2014

LooksCam II in the run.
LooksCam II Xenosys in the run  starting from  14-March-2021 with SheerVision TTL x4 magnification.


Notice: Not all operative activities can be recorded due to lack of time.
Notice: Head injuries and very urgent surgeries are also escaped from the plan .


 

 

 

WELCOME TO AL-SHMAISANI HOSPITAL

 


View Larger Map

© [2003] [CNS CLINIC - NEUROSURGERY - JORDAN]. All rights reserved